Skip to content

The v1 docs follow nauthera-server's main branch and its 0.x releases on the way to 1.0, so fields and APIs can still change.

v1

insufficient_scope

Docs version v1 (main)Nauthera is pre-1.0, in a design-partner program

The access token is valid but does not carry the scope the operation requires (RFC 6750 §3.1).

Meaning

Sent as 403 with a WWW-Authenticate: Bearer error="insufficient_scope", scope="..." challenge, never in a token-endpoint body. The scope parameter names what the operation needs. Today it comes from the admin API, where the token lacks the nauthera. admin scope the route's permission maps to; from dynamic registration (/register), where an initial access token lacks nauthera.clients:register; and from the service attribute API (PATCH /v1/user-attributes/users/{user_id}), where a client's token lacks nauthera.user-attributes:write. The body of a registration refusal says access_denied, because RFC 7591 §3.2.2 has no insufficient_scope code.

Impact

The caller is authenticated but may not perform this operation with this token. It is a configuration fault on the client's side, not an attack: the token was granted narrower than the call needs. Nothing was read or changed.

Diagnosis

  1. Read the scope parameter of the response's WWW-Authenticate header: it is the scope the operation requires.
  2. Decode the access token and compare its scope claim with that value.
  3. Admin API refusals are recorded with reason missing_scope; registration refusals as client.registration.attempted with cause insufficient_scope; service attribute writes as user.updated, denied with reason insufficient_scope. Find either on the dashboard's Troubleshooting page by X-Request-ID.
  4. Check that the client is registered for the scope (spec.scopes on its OIDCClient, or allowed_scopes of the registration policy) and that the token request asked for it.

Mitigation

  • As a client developer: request a token with the scope the challenge names, and register the client for it first if it is not.
  • As an operator: add the scope to the client's registration, or, for the admin API, grant the caller a role whose permissions map to it.

Escalation

If a token that carries the named scope is still refused, open an issue with the request id, the server version and the route. Never attach the token itself.


OAuth error runbooks · Generated from internal/runbook/oauth.yaml in nauthera-server.